X-ray CT system - List of Manufacturers, Suppliers, Companies and Products

X-ray CT system Product List

1~15 item / All 15 items

Displayed results

3D X-ray CT system "3DCT Series"

Capable of handling a wide range of work from high power to low power!

The "3DCT Series" is a three-dimensional X-ray CT system that utilizes our unique technology, the U-Centric (focus-centered rotation) function, allowing for 360-degree perspective observation and high-magnification CT imaging of the focused point with "microscopic vision" and even "nanoscopic vision." We offer a lineup that includes the ultra-high-resolution model "XVA-160αII," which achieves ultra-high magnification (2,000 times) and a nano-order focus size (250/800nm), as well as the standard model "XVA-160R" and the wide-range model "Si-230/300." These systems are widely adopted for the non-destructive analysis of compact, high-density, and multi-layered high-function electronic components with high precision. 【Features of "XVA-160αII 'Z'】 This ultra-high-resolution model achieves ultra-high magnification (2,000 times) and nano-order size (250/800nm). There are imaging examples such as transmission images and tomographic images of fingerprint sensors, as well as tomographic images of electromigration. It is equipped with numerous features, including the U-Centric function, optical axis, rotation center, and automatic focus adjustment functions. *For more details, please refer to the PDF materials or feel free to contact us.*

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

X-ray CT system imaging example: CT cross-section of solder cracks

Introducing a case study of tomographic imaging of solder cracks inside semiconductors captured using a micro-focus X-ray CT system!

The micro-focus X-ray CT system 'XVA-160RZ' is an X-ray CT system that can visualize high-resolution fine internal structures used in applications such as non-destructive testing and material analysis. You can choose between a high-resolution type and a wide-field type. This time, we will introduce a case study of the micro-focus X-ray CT system 'XVA-160RZ'! It is a case where a cross-section of solder cracks inside a semiconductor was captured. 【Details】 ■ Industry of the company that introduced the system Semiconductor, electronic components, and electronic equipment manufacturing ■ Purpose of introduction Quality assurance, failure analysis ■ Effects of introduction Increased productivity due to improved success rate of failure analysis Improved yield due to faster identification of defect causes *For more details, please check the PDF download.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Case] CT Cross-section of Solder Crack

This is a case where a micro-focus X-ray CT system XVA-160RZ was used to perform CT imaging of an interposer substrate, detecting solder cracks.

The XVA-160RZ is a versatile 3D X-ray CT system that can be used for quality assurance, failure analysis, and inspection of semiconductors, electronic components, and electronic modules. By utilizing functions such as real-time observation, 3D oblique CT, and orthogonal CT according to the application, it not only facilitates efficient analysis work but also dramatically improves the success rate of analyses. Additionally, by using the standard program operation function, it can also be employed for product sorting and sampling inspection purposes.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Example] QFP_Wire

This is a case of performing orthogonal CT imaging of the wire bonding section inside a QFP using the Micro Focus X-ray CT system XVA-160RZ.

This is an example of a QFP (Quad Flat Package) captured using orthogonal CT. It is possible to closely observe even the indentations from the second bonding of the wires. The XVA-160RZ allows for easy orthogonal CT imaging simply by attaching a dedicated unit without the need to change the stage. Similar to oblique CT, orthogonal CT can also be performed at high magnification.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Example] Smartphone Internal Circuit Board

This is a case of CT imaging of a smartphone's internal circuit board. It is possible to observe the patterns and structures of each internal layer.

The "XVA-160αII 'Z'" is a nano-focus X-ray CT system used in applications such as non-destructive testing and material analysis. This system is an ultra-high-resolution model that achieves ultra-high magnification (2000 times) and nano-order sizes (250/800nm). The patterns of each internal layer are captured clearly. The condition of the fillet and the mounting state are also visible in a way unique to CT imaging.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-output X-ray CT system "CT Compact"

High-output 450kV mini-focus X-ray tube! Compatible with a wide variety of samples.

The "CT Compact" is a high-output X-ray CT system that accommodates a wide variety of samples, from high-density workpieces such as castings to composite modules. It uses a high-output 450kV mini-focus X-ray tube. It can be equipped with two types of detectors: a line detector that minimizes the influence of scattered rays and a flat panel detector (optional). 【Features】 ■ Accommodates a wide variety of samples, from high-density workpieces such as forged products to composite modules ■ High-output 450kV mini-focus X-ray tube ■ Two types of detectors can be installed Company name: YXLON *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Analysis Equipment
  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-resolution measurement X-ray CT system 'FF35 CT'

Introducing a high-resolution measurement X-ray CT system featuring low thermal expansion granite stages!

The "FF35 CT" is a high-resolution measurement X-ray CT system capable of accommodating two types of X-ray tubes: a reflection type at 225kV and a transmission type at 190kV (optional). It can handle a wide variety of samples, from fine work such as CFRP to small electronic components and cast parts. As an option, we offer a measurement accuracy of 8μm + L/75 [L = mm] (for measurement use) and a helical CT suitable for imaging laminated materials. 【Features】 ■ Supports a wide variety of samples ■ Capable of accommodating two types of X-ray tubes ■ Measurement accuracy of 8μm + L/75 [L = mm] (measurement CT option) ■ Helical CT suitable for imaging laminated materials (optional) ■ Granite stage with low thermal expansion rate Company Name: YXLON *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Analysis Equipment
  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【UHS_X-ray CT System Imaging Case】QFP Observation Case

This is a case of CT imaging of a QFP using the Micro Focus X-ray CT system XVA-160RZ.

This is an example of a QFP (Quad Flat Package) captured using orthogonal CT. It allows for detailed observation of the internal chip patterns. The XVA-160RZ enables easy orthogonal CT imaging simply by attaching a dedicated unit without the need to change the stage. Similar to oblique CT, orthogonal CT can also be performed at high magnification.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Example] Electrolytic Capacitor

This is a case of CT imaging of an electrolytic capacitor using the Micro Focus X-ray CT system XVA-160RZ.

This is a case of a conductive polymer aluminum solid electrolytic capacitor imaged using transmission imaging and oblique CT scanning. It allows for the confirmation of internal structures and observation of solder conditions. The XVA-160RZ is a standard model that can widely observe various defects in a diverse range of workpieces. Additionally, it is a device that can contribute to the efficiency of analysis, as it can perform CT scanning in just three and a half minutes.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【UHS_X-ray CT System Imaging Case】Heated Tobacco

This is a case of transmission imaging of heated tobacco using the Micro Focus X-ray CT system XVA-160RZ.

This is an example of a heated tobacco product captured through transmission imaging. It allows for understanding the internal substrate condition and structure. The XVA-160RZ can perform orthogonal CT imaging easily by simply attaching a dedicated unit without changing the stage. Similar to oblique CT, orthogonal CT can also be captured at high magnification.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Case] First Generation Smartphone

This is a case of the first-generation smartphone captured with a transparent image and oblique CT scan. It allows for the observation of the internal structure and the condition of the internal memory.

The "XVA-160RZ" is a micro-focus X-ray CT system used in applications such as non-destructive testing and material analysis. This system can visualize fine internal structures with high resolution. Additionally, you can choose between a high-resolution type and a wide-field type. This time, we will introduce a case study of the micro-focus X-ray CT system "XVA-160RZ"!

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Case] Smartphone (2018)

This is a case of a smartphone (2018 model) that was imaged using transparent imaging and angled CT scanning. It allows for the observation of the internal structure and the condition of the internal memory.

The "XVA-160RZ" is a micro-focus X-ray CT system used in applications such as non-destructive testing and material analysis. This system can visualize fine internal structures with high resolution. Additionally, you can choose between a high-resolution type and a wide-field type. This time, we will introduce shooting examples of the micro-focus X-ray CT system "XVA-160RZ"! On a separate page, we have published the first-generation smartphone. Changes in the internal structure can be observed comparatively.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[UHS_X-ray CT System Imaging Example] microSD WB

This is a case of wire bonding imaged using the "NanoFocus X-ray CT System XVA-160αII 'Z'."

This is an example of an image taken with oblique CT of microSD wire bonding. The wire bonding can be clearly observed. The "XVA-160αII 'Z'" is a nano-focus X-ray CT system used in applications such as non-destructive testing and material analysis. This system is a super high-resolution model that achieves ultra-high magnification (2,000 times) and nano-order sizes (250/800nm).

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

3D X-ray CT system 'XVA-160RA/160αII "Z"'

Easily achieve high magnification observation with the unique technology "User-Centric Mechanism." New products are showcased at "Electro Test Japan."

Our company offers a 3D X-ray CT system that employs our unique technology, the "U-Centric Mechanism," enabling easy and efficient observation at high magnification. In diagonal CT imaging, bringing the target area closer to the X-ray focus allows for high-magnification tomographic imaging. This enables detailed observation and strongly supports the discovery and analysis of defects in printed circuit boards and semiconductor devices. 【Features】 ◎ 'XVA-160RA' ■ A newly revamped model based on the standard model, compatible with high-resolution generators ■ Equipped with a nano-focus X-ray generator (focus size 250/800nm) ■ Allows for clear observation of details at a magnification of 1,600 times ■ Includes visible light mapping function and automatic focus adjustment function ◎ 'XVA-160αII "Z"' ■ A high-end model specialized for even higher magnification, capable of analyzing the internal structure of packages ■ Equipped with a nano-focus X-ray generator (focus size 200nm and above) ■ Allows for precise observation of detailed structures at a magnification of 2,000 times ■ Includes a high-resolution top table, automatic adjustment functions for optical axis, rotation center, and focus ★ Our company will exhibit at "Electrotest Japan," held at Tokyo Big Sight from January 22 (Wednesday).

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【X-ray CT system imaging example】CT tomography with a smartphone-mounted CPU

Introducing a CT imaging case of a smartphone-mounted CPU captured with a micro-focus X-ray CT system!

The "XVA-160RZ" is a micro-focus X-ray CT system used in applications such as non-destructive testing and material analysis. This system can visualize fine internal structures with high resolution. Additionally, users can choose between a high-resolution type and a wide-field type. This time, we would like to introduce a case study of the micro-focus X-ray CT system "XVA-160RZ"! It is a case where a CT scan of a smartphone-mounted CPU was performed. 【Details】 ■ Industry of the company that introduced the system Semiconductor, electronic components, and electronic equipment manufacturing ■ Purpose of introduction Quality assurance, failure analysis ■ Effects of introduction Increased productivity due to improved success rate of failure analysis tasks Improved yield due to faster identification of defect causes *For more details, please check the PDF download.

  • Non-destructive testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration